Normal view MARC view ISBD view

Development and validation of stability indicate RP-HPLC method for simultaneous determination of aspirin, rosuvastatin, clopidogrel in bulk and pharmaceutical dosage form

By: Pisal, Pooja.
Contributor(s): Nigade, Ganesh | Kale, Amol.
Publisher: M. P. Innovare Academic Sciences Pvt Ltd 2018Edition: Vol. 10(10), July-August.Description: 50-56.Subject(s): PHARMACEUTICSOnline resources: Click here In: International journal of pharmacy and pharmaceutical scienceSummary: Objective:To develop a novel, accurate, precise and linear reverse phase high-performance liquid chromatography (RP-HPLC) and Stability Indicating Assay Method (SIAMs) for simultaneous, qualitative and quantitative estimation of aspirin, rosuvastatin and clopidogrel in bulk and pharmaceutical dosage form as per International Conference on Harmonization (ICH) guidelines.Method: In the present work, good chromatographic separation was achieved by isocratic method using a BISCOF HPLC C18 Results: The retention time of aspirin, rosuvastatin, and clopidogrel was found to be 4.3 min, 7.6 min and 16.6 min respectively. For linearity seven-point calibration curves were obtained in a concentration range from 1-7 μg/ml for aspirin, rosuvastatin and clopidogrel with correlation coefficient 0.999, 0.9989, 0.9988 respectively. The high recovery values (99%-101%) indicate a satisfactory accuracy. The low percent relative standard deviation (% RSD) values in the precision study reveal that the method is precise. In the present study stability indicating an RP-HPLC method for the combination was tested by degrading the drugs together under various stress condition like acid, base and neutral hydrolysis, oxidation, thermal and photolytic stress which is recommended by ICH.column (250 mm ×4.6, 5 μm) and a mobile phase consisting of water at pH 2.51 with 0.1 % (v/v) orthophosphoric acid (OPA): acetonitrile in the ratio 50:50, at a flow rate of 1 ml/min. The effluents obtained were monitored at 237 nm with the UV-visible detector.Conclusion: The developed RP-HPLC method is simple, economic, specific, accurate and precise for the simultaneous estimation of aspirin, rosuvastatin, and clopidogrel in the combined capsule dosage form. The developed stability indicating analytical meth....
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Pharmacy
Archieval Section
Not for loan 2018416
Total holds: 0

Objective:To develop a novel, accurate, precise and linear reverse phase high-performance liquid chromatography (RP-HPLC) and Stability Indicating Assay Method (SIAMs) for simultaneous, qualitative and quantitative estimation of aspirin, rosuvastatin and clopidogrel in bulk and pharmaceutical dosage form as per International Conference on Harmonization (ICH) guidelines.Method: In the present work, good chromatographic separation was achieved by isocratic method using a BISCOF HPLC C18 Results: The retention time of aspirin, rosuvastatin, and clopidogrel was found to be 4.3 min, 7.6 min and 16.6 min respectively. For linearity seven-point calibration curves were obtained in a concentration range from 1-7 μg/ml for aspirin, rosuvastatin and clopidogrel with correlation coefficient 0.999, 0.9989, 0.9988 respectively. The high recovery values (99%-101%) indicate a satisfactory accuracy. The low percent relative standard deviation (% RSD) values in the precision study reveal that the method is precise. In the present study stability indicating an RP-HPLC method for the combination was tested by degrading the drugs together under various stress condition like acid, base and neutral hydrolysis, oxidation, thermal and photolytic stress which is recommended by ICH.column (250 mm ×4.6, 5 μm) and a mobile phase consisting of water at pH 2.51 with 0.1 % (v/v) orthophosphoric acid (OPA): acetonitrile in the ratio 50:50, at a flow rate of 1 ml/min. The effluents obtained were monitored at 237 nm with the UV-visible detector.Conclusion: The developed RP-HPLC method is simple, economic, specific, accurate and precise for the simultaneous estimation of aspirin, rosuvastatin, and clopidogrel in the combined capsule dosage form. The developed stability indicating analytical meth....

There are no comments for this item.

Log in to your account to post a comment.
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha